PCNET_Cable
1994~1999 Invested in LAN Cable production lines & HP analyzer. Cat.5 UTP/FTP solid cable & patch cord came into mass production. Cat.5e UTP/FTP solid cable & patch cord came into mass production. Cat.7 F-FTP Freq. ( MHz ) Ins. Loss Pair to Pair NEXT ELFEXT NEXT ELFEXT Power Sum Delay Skew Po. Delay ( ns/100m ) ( ns/100m ) ( dB/100m ) ( dB/100m ) ( dB/100m ) Max. Max. Max. Min. Min. Min. Min. ( dB ) 1 4 10 16 20 31.25 62.5 100 200 250 400 500 600 2.1 3.7 5.9 7.4 8.3 10.4 14.9 19.0 27.5 31.0 40.0 45.3 50.1 20.0 23.0 25.0 25.0 25.0 23.6 21.5 20.1 18.0 17.3 17.3 17.3 17.3 78.0 78.0 78.0 78.0 78.0 78.0 75.5 72.4 67.9 66.4 63.4 61.9 60.7 78.0 78.0 75.3 71.2 69.3 65.4 59.4 55.3 49.3 47.3 43.3 41.3 39.7 75.0 75.0 75.0 75.0 75.0 75.0 72.5 69.4 64.9 63.4 60.4 58.9 57.7 75.0 75.0 72.3 68.2 66.3 62.4 56.4 52.3 46.3 44.3 40.3 38.3 36.7 25 25 25 25 25 25 25 25 25 25 25 25 25 570.0 552.0 545.4 543.0 542.0 540.4 538.6 537.6 536.5 535.3 535.8 535.6 535.5 67304 67904 4 4 F-FTP S-FTP 23AWG 23AWG 1.32 1.34 7.95 8.05 76.5 76.5 Jacket : PVC, LSZH ( Low Smoke Zero Halogen ) , Outdoor PE Packaging : 305M / 500M Wooden Reel Mylar Foil Jacket Overall Mylar Foil lnsulation Conductor Drain Wire Electrical Performance Order Information 4 Meet IEC 61156-5 Ed.2.0 Category 7 horizontal cable parameters Part No. No. of Pairs Cable Type NVP (%) Conductor Size Core Dimension ( mm ) Overall Dimension ( mm ) RL Min. Note: The cable performance between 1MHz and 4MHz is achieved by designed only and it is therefore not necessary to test for this performance below 4MHz.