PCNET_Cable

Cat.6A U-FTP Cat.6A S-FTP 2000 Invested in accessories factory & gas injection extrusion. RG Coaxial gas injection type ready for production. Insulation Conductor Jacket Braiding Mylar Foil Mylar Foil Conductor Jacket Insulation Drain Wire Drain Wire Freq. ( MHz ) Ins. Loss Pair to Pair NEXT ELFEXT NEXT ELFEXT Power Sum Delay Skew Po. Delay ( ns/100m ) ( ns/100m ) ( dB/100m ) ( dB/100m ) ( dB/100m ) Max. Max. Max. Min. Min. Min. Min. ( dB ) 1 4 10 16 20 31.25 62.5 100 200 250 300 400 500 2.1 3.8 5.9 7.5 8.4 10.5 15 19.1 27.6 31.1 34.3 40.1 45.3 20.0 23.0 25.0 25.0 25.0 23.6 21.5 20.1 18.0 17.3 17.3 17.3 17.3 75.3 66.3 60.3 57.2 55.8 52.9 48.4 45.3 40.8 39.3 38.1 36.3 34.8 68.0 56.0 48.0 43.9 42.0 38.1 32.1 28.0 22.0 20.0 18.5 16.0 14.0 72.3 63.3 57.3 54.2 52.8 49.9 45.4 42.3 37.8 36.3 35.1 33.3 31.8 65.0 53.0 45.0 40.9 39.0 35.1 29.1 25.0 19.0 17.0 15.5 13.0 11.0 45 45 45 45 45 45 45 45 45 45 45 45 45 570.0 552.0 545.4 543.0 542.0 540.4 538.6 537.6 536.5 536.3 536.1 535.8 535.6 66504A1 66304A 66304BA 66704A 66904A 66304BA1 * 4 4 4 4 4 4 U-UTP F-FTP U-FTP F-UTP S-FTP U-FTP 23AWG 23AWG 23AWG 23AWG 23AWG 26AWG 1.03 1.32 1.32 1.1 1.34 0.93 8.3 7.59 7.47 7.73 8.05 5.59 66.7 76.5 76.5 66.7 76.5 72.9 Jacket : PVC, LSZH ( Low Smoke Zero Halogen ) , Outdoor PE Packaging : 305M / 500M Wooden Reel * Zone Cable / Application length : 60M (Max) Electrical Performance Order Information 6 MEET IEC 61156-5 Ed.2.0 Category 6A horizontal cable parameters Part No. No. of Pairs Cable Type Conductor Size NVP (%) Core Dimension ( mm ) Overall Dimension ( mm ) RL Min. Note: The cable performance between 1MHz and 4MHz is achieved by designed only and it is therefore not necessary to test for this performance below 4MHz.

RkJQdWJsaXNoZXIy ODM5NzM=